Scale removal, rust prevention, and corrosion protection | QCL-DC Electronic Scale Remover

The electronic scale remover uses resonant electron technology to remove scale from pipes and heat exchangers.Prevent and remove scaleIt's a device.

This is ideal for this type of equipment.

  • cooling tower
  • heat exchanger
  • boiler
  • Piping equipment
  • Factory circulating water

In addition, it is suitable for all types of water-based facilities prone to scale buildup.

Retail

Features and Benefits

01

Prevent scaling.

  • Prevention rate over 95%
  • Existing scales are also gradually removed.

02

  • Improved heat exchange efficiency
  • Energy loss reduction
  • Reduced maintenance load

03

Don't rely on medication.

  • No medication required
  • No changes to water quality.
  • Equipment load reduction

Performance and Design

Reliable performance and design

QCL-DC 電子スケール除去器 製品画像
01

Automatically adjusts according to water quality

Automatically adjusts frequency for stable operation tailored to site conditions.

02

Electrode life 20 years

It uses a highly durable special alloy and is designed for long-term use.

03

International standard transformer

By employing international standard transformers, stable operation is ensured.

04

Simple structure

Shield design that increases work efficiency by more than 30%.

Compatible bore diameters DN15mm-200mm

It can accommodate a wide range of pipe diameters.

*The photo shows a flange connection, but the Japanese specification uses a screw connection.
*There are two types: one with an integrated circuit box (pictured) and one with a separate circuit box.

PRINCIPLE

Why can the pipes be protected?

Electronic control technology suppresses scaling and corrosion.

01
O₂

Suppresses oxygen.

It inactivates oxygen in the water, suppressing the progression of corrosion.

02
Fe²⁺

Protects the surface of the pipes.

It controls the distribution of electrons and suppresses the elution of metal ions.

03
Fe₂O₃ → Fe₃O₄

Converts red rust to black rust.

Existing red rust is transformed into highly durable black rust.

EFFECT

Implementation effects

By minimizing the causes of equipment malfunctions, we aim for stable operation.

Before

Challenges before implementation

  • Reduced heat exchange efficiency
  • Scale deposition
  • Red rust
  • Medication management
→
After

Effects after implementation

  • Scaling suppression
  • black rust
  • Maintenance reduction
  • Stable operation

CASE STUDY

Previous cases

We have confirmed the scale suppression effect in actual piping and equipment.

CASE 01

Flange piping

Before use 使用前の配管内部
→
After use 使用後の配管内部
CASE 02

Inside the pipe

Before use 使用前の配管内部
↓
After use 使用後の配管内部

DOCUMENTS

You can view product information and company profiles all in one place.

Scroll to Top